skillissuer
i should be writing
any explosive weapon will sometimes leave duds, there are GMLRS, javelin and excalibur duds documented. ww1 era shells could be the worst because by some estimates up to some 20% failed, then fuzes were often brass so they didn’t corrode, but shell or bomb body were steel or cast iron so they did. when fuze gets almost set off then loses mechanical support it sometimes becomes more likely it’ll be initiated on its own
that would be 25-35 reactors, as long as cooling is available you can just put them in one place. 5GW is around size of largest european nuclear powerplants (Zaporozhian, 5.7GW; Gravelines, 5.4GW; six blocks each) or around energy consumption of decently-sized euro country like Ireland, Hungary or Bulgaria. 25GW is electricity consumption of Poland, 30GW UK, 35GW Spain
this is not happening hardest because by the time they’d get permits for NPP they’ll get bankrupt because bubble will be over
and now when somebody will generate exactly the same thing, it won’t be new stuff either el reg: Hipster whines at tech mag for using his pic to imply hipsters look the same, discovers pic was of an entirely different hipster
fuck this horseshit, half of my publishing is with wiley. is there a shop out there that doesn’t feed all of its papers to wisdom woodchipper?
find the point where the idea of taking psychedelics went from “they’ll make you a better (more egalitarian/antifascist) person” to “they’ll make you a more efficient capitalist monster”.
i think it happened somewhere around the time when microdosing got popular as an idea since that made psychedelics more palatable for normies. 2015ish i think?
you don’t need a lot of computers there, it all can even work without communication with power company. on medium voltage (15kV) lines, that would be reclosers every few kilometers, and these do trip when short to ground (>0.5A) is detected. but no one does that on low voltage, because potential for damage is much less. the difference between euro and american grids is that americans have medium voltage line going down every single street, and because of low voltages and high power draw conductors would have to be of monstrous size otherwise. i understand that GFCIs are rather uncommon out there, and these aren’t usually installed in substations either. there are also lots of smaller transformers in american grid and that would make costs of putting all that protection circuitry even higher (in my home village there was 1 15/0.4kV substation per some 250 people, or 80ish houses. americans can have one transformer per one house) gas line could be plastic, so it would be isolating and so it’d be limited to that one house